Interior:

Inside |

HDD Rack |

Vibration damper |
The side panel is secured in place with two thumbscrews and once those are
removed, pull the latch and the door pulls away from the enclosure. Once inside,
you will notice that the clean look extends itself to the interior. The hard
drive rack, which sits sideways, has four slots. In those slots are removable
trays with silicone rubber grommets to reduce HDD vibration.

EarthWatts PSU |

120mm TriCool fan |
One thing sticking out in the
Sonata III is the power supply; it's not too often
that a power supply is included with enclosures. The
EarthWatts 500W PSU is the power supply that is included with the Sonata III.
Back in April, 2007 I reviewed that very same power supply with good results.
Below the PSU is one 120mm exhaust fan with the TriCool speed control.
PSU Specs:
|
FEATURES
|
|
Switches
|
ATX Logic
on-off
Additional
power rocker
switch
115/230 Volt
selector
switch
|
|
Maximum
Power
|
500W
|
|
Transient
Response |
+5V,+12V and
3.3V outputs
return to within
5% in less than
1ms for 20% load
change.
|
|
P. G. Signal
|
100-500ms
|
|
Over Voltage
Protection
recycle AC to
reset
|
+5V trip point <
+6.2V
+3.3V trip point
< +4.1V
+12V trip point
< +14.3V |
|
Special
Connectors
|
ATX12V
SATA
PCI Express |
|
Leakage Current
|
<3.5mA @ 115VAC
|
|
DIMENSIONS
|
|
Unit Size
|
5.9"(W) x
3.4"(H) x
6.1"(D)
14.9cm (W)x
8.5cm (H) x
15.8cm (D) |
|
Net Weight
|
5lbs.2.3kg |
|
OUTPUT
|
|
|
+5V
|
+12V1
|
+12V2
|
+3.3V
|
-12V
|
+5Vsb
|
|
Max. Load
|
20A |
17A |
17A |
20A |
0.8A |
2.5A |
|
Min. Load
|
0.5A
|
1A |
1A |
0.5A |
0A |
0A |
|
Load Reg.
|
±3%
|
±3%
|
±3%
|
±3%
|
±5%
|
±5%
|
|
Ripple
m(p-p)
|
50 |
120 |
120 |
50 |
120 |
50 |
* Total: +12V
output: 34A
* +5V and +3.3V
combined output:
34.2A
|
|
INPUT
|
|
Input Voltage
|
115 VAC / 230VAC |
|
Input Frequency
Range
|
60Hz/50Hz |
|
Inrush Current |
640A @ 115V ,
100A @ 230V |
|
Input Current
|
12A @ 115V, 6A @
230V |
|
Hold-up Time
|
20ms at full
load |
|
Efficiency
|
up to 85%
|
|
EMI/RFI
|
FCC Class B
|
|
ENVIRONMENTAL
|
|
Operating Temp.
|
10°C to 50°C
|
|
Operating Alt.
|
Sea Level-10,000
ft |
|
MTBF
|
80,000 hours at
25’C |
|
Safety Approval |
TUV, UL, CUL,
CE, CB, FCC,
C-Tick, CCC
|
|
|